Çѱ¹NI ±³À°¼¾ÅÍ °­»ç¼Ò°³ ³»°Ô ¸Â´Â ±³À°°úÁ¤ ã±â ¼ö°­»ý °Ô½ÃÆÇ ±³À°Èıâ ÀÇ°ß ¹× ¹®ÀÇ °­ÀÇ Æò°¡Çϱâ
 
LabVIEW Çϵå¿þ¾î °úÁ¤
Real Time 2 ¾îÇø®ÄÉÀÌ¼Ç °³¹ß°úÁ¤ ÀÎ¼â   ¸ÞÀϹ߼Û
±³À°±â°£ : 2ÀÏ
ÇÊ¿äÇÑ ÄíÆù °³¼ö : 2°³
¼ö°­´ë»ó :
 

Real Time Ÿ°Ù(Çϵå¿þ¾î)¸¦ »ç¿ëÇÏ¿© ¾îÇø®ÄÉÀÌ¼Ç °³¹ßÀÌ ÇÊ¿äÇÑ »ç¿ëÀÚ
º¸À¯ÇÑ Real Time ¾îÇø®ÄÉÀ̼ÇÀ» À§ÇÑ °í±Þ Åë½Å ¹æ¹ý, º¥Ä¡¸¶Å·, ÃÖÀûÈ­µÈ ÃøÁ¤ ½Ã½ºÅÛÀ» ±¸¼ºÇϰíÀÚ ÇÏ´Â °³¹ßÀÚ
ÃÖ´ëÇÑÀÇ ½Å·Ú¼ºÀ¸·Î Real Time ¾îÇø®ÄÉÀ̼ÇÀ» °³¹ßÇϰíÀÚ ÇÏ´Â »ç¿ëÀÚ

¼±¼ö°úÁ¤ : LabVIEW Core I (Çʼö), Real Time 1, LabVIEW Core II (±ÇÀå) ±³À°°úÁ¤ ¼ö°­ ȤÀº »óÀÀÇÏ´Â ÇÁ·Î±×·¡¹Ö °æÇè
°úÁ¤°³¿ä
  Real Time ¾îÇø®ÄÉÀ̼ÇÀ» À§ÇÑ ¿ä±¸µé°ú µðÀÚÀÎ È®ÀÎ ¹æ¹ý
¸ÖƼÇà Ÿ°ÙÁß¿¡ °¡Àå ÀûÇÕÇÑ RT Ÿ°ÙÀÇ µ¥ÀÌÅÍ ½¦¾î¸µ ¹æ¹ý »ç¿ë
³×Æ®¿öÅ©¸¦ ³Ñ¾î RT Ÿ°Ù°ú È£½ºÆ® ÄÄÇ»ÅÍ »çÀÌ¿¡ °¡Àå ÀûÇÕÇÑ Åë½Å ¹æ¹ý »ç¿ë
±¸Ã¼ÀûÀ̰í Áß¿äÇÑ ¿¡·¯ Çڵ鸵ÀÇ ¼öÇà
Real-Time ¾îÇø®ÄÉÀ̼ÇÀÇ ½Å·Ú¼º Áõ°¡¸¦ À§ÇÑ ´Ù¾çÇÑ Å×Å©´Ð ¼öÇà
Real-Time ÄÚµå º¥Ä¡¸¶Å© ¹× ºÐ¼®
´Ù¾çÇÑ ÃÖÀûÈ­ Å×Å©´Ð »ç¿ë
±³À°¸ñÂ÷¿Í ±³Àç »ùÇú¸±â
ÀÏÀÚº° ±³À°³»¿ë
1ÀÏ
Real Time ¾îÇø®ÄÉÀ̼ÇÀ» À§ÇÑ ¿ä±¸»çÇ×µé°ú µðÀÚÀÎ ±¸º°
Identifying tasks
Identifying performance requirements
Identifying task timing
Identifying data transfer relationships
Identifying reliability issues
°í±Þ RT IntertaskÅë½Å ¹æ¹ý
Comparing shared variables and RT FIFO funtions
Using functional global variables for encapsulation, circular buffer, and current value tables
°í±Þ RT Network Åë½Å ¹æ¹ý
Methods of monitoring latest values
Using web services
Managing streaming data
Implementing a commander-worker design
2ÀÏ
½Å·Ú¼º
Specific error handling
Central error handling
Monitoring your system
Implementing a watch dog
Implementing a network heartbeat
Redundancy
º¥Ä¡¸¶Å· ¹× Validation
Benchmarking performance and code duration
Creating a time budget
Examining traces using Real-Time Execution Trace Toolkit
ÃÖÀûÈ­
Avoiding shared resources
Avoiding dynamic memory allocations
Comparing polling and blocking
Symmetric Multiprocessing (SMP)
Various optimization technique
À̼ö ÈÄ ´ÙÀ½°úÁ¤
 

LabVIEW FPGA
LabVIEW Core 3
Data Acquisition and Signal Conditioning

°øÅë»çÇ×
±³À°½Ã°£ : 9½Ã 30ºÐ ~ ¿ÀÈÄ 5½Ã 30ºÐ (Á¡½É½Ã°£ 12½Ã ~ 1½Ã 30ºÐ)
Ãë¼Ò±ÔÁ¤, À¯È¿±â°£, ÃÖ¼ÒÀοø ¹Ì¸¸ µî ±³À°µî·Ï È®ÀÎ »çÇ×
°­ÀǺñ¿ë Æ÷ÇÔ³»¿ë : °­ÀÇ, ±³Àç, ±³À°Àåºñ, °£´ÜÇÑ Á¶½Ä, Áᫎ Æ÷ÇÔ, (¼®½Ä/¼÷¹Ú, ÁÖÂ÷ºñ Æ÷ÇÔµÇÁö ¾ÊÀ½)
±³Àç ¹ß¼Û¾È³»
±³À°°úÁ¤Àº À̷аú ¿¬½À¹®Á¦ Ç®À̰¡ º´ÇàµÇ¾î ±³À° ±â°£µ¿¾È °­µµ ³ô°Ô ÁøÇàµË´Ï´Ù. ¹Ì¸® ±³Àç È帧°ú ÇÔ¼ö À§Ä¡µî ±³Àç ¿¹½ÀÀ» ÇÏ°í ¼ö°­ÇÏ½Ã¸é ¼ö°­È¿°ú¸¦ º¸½Ã´Âµ¥ ¹«Ã´ µµ¿òÀÌ µË´Ï´Ù. ±³À°µî·Ï, ±³À°ºñ¿ë °áÁ¦¸¦ ¿Ï·áÇÏ½Ã¸é ±³À縦 Åùè¹ß¼Û ÇÕ´Ï´Ù.
±³À°Àå ¾È³»
»çÀÌÆ®¸Ê | ¸ÞÀϺ¸³»±â | °³ÀÎÁ¤º¸º¸È£Á¤Ã¥ | °ü·Ã»çÀÌÆ® |À̸ÞÀÏÁÖ¼Ò ¹«´Ü¼öÁý°ÅºÎ | NI °­»çº¸±â
¼­¿ï½Ã °­³²±¸ »ï¼ºµ¿ 169¹øÁö ´ëÈ­ºôµù Çѱ¹³»¼î³¯ÀνºÆ®·ç¸ÕÆ®(ÁÖ) »ç¾÷ÀÚ µî·Ï¹øÈ£ : 214-81-91583
TEL : 02-3451-3400 FAX : 02-3451-3451 Copyright ¨Ï National Instruments Corporation. All rights reserved.